ProCurve 2910al Switches Installation and Getting Started Guide

HP Switch Software Basic Operation Guide

Factory reset

To execute the factory default reset on the switch, perform these steps:

  1. Using pointed objects, simultaneously press both the Reset and Clear buttons on the front of the switch.
  2. Continue to press the Clear button while releasing the Reset button.
  3. When the Self Test LED begins to blink, release the Clear button.

The switch will then complete its self test and begin operating with its configuration restored to the factory default settings.

The factory default uses a baud rate of 9600.

Serial console

Recommendation: use sio to access the serial terminal.

sudo tio --baudrate 115200 /dev/ttyS0

Quit with CTRL+t, q

Turn pager off: no page

Change screen length: screen-length 50

Configuration

Bauwagen

Ports

console baud-rate 115200
write memory
reload

conf t

vlan 2 name jugendtreff
vlan 2 qos priority 1
vlan 2 tagged 23,24

vlan 6 name public-event
vlan 6 qos priority 0
vlan 6 tagged 21-24

vlan 7 name weinturm
vlan 7 qos priority 1
vlan 7 tagged 21-24
vlan 7 untagged 1-12

vlan 8 name voice
vlan 8 qos priority 5
vlan 8 tagged 21-24
vlan 8 untagged 17,19
vlan 8 voice

interface ethernet 1-12 enable

interface ethernet 17,19 enable
interface ethernet 17,19 name dect

interface ethernet 21 name kleinturm-copper
interface ethernet 22 name kleinturm-fiber
interface ethernet 22 speed-duplex 1000-full

interface ethernet 23 name pbx
interface ethernet 23 enable
interface ethernet 23 speed-duplex auto-1000

interface ethernet 24 name uplink
interface ethernet 24 speed-duplex 1000-full

vlan 1 forbid 1-12,17,19,21-24

  • WLAN AP
  • DECT OMM
  • Kleinturmbühne
  • Photoprism-Server